Engineering networks

Security systems design engineering

We produce detailed designs for fire protection, security and low-voltage systems that you can build from, commission the site with and maintain the system by for years.

Detailed designDBNCalculationsSpecificationsCost estimateDesigner supervision

A design is not a formality

A good design determines whether the system will work when it is needed. It sets out the location of every device, cable routes, power, the interaction logic between systems and the equipment specification. It is what the system is installed, commissioned and maintained by for years.

What we design

  • Fire protection: fire alarm, voice alarm and evacuation, smoke extraction and pressurization, automatic fire suppression, internal fire hydrant systems.
  • Security: access control, video surveillance, intruder alarm, perimeter protection.
  • Low-voltage networks: structured cabling, fiber optics, public address, building monitoring.

What a detailed design includes

  • an explanatory note justifying the solutions with references to the codes;
  • floor plans showing equipment locations and cable routes;
  • block and schematic diagrams;
  • system interaction logic (cause-and-effect matrix);
  • loop, power and battery capacity calculations, plus airflow and hydraulic calculations for smoke control and fire suppression;
  • equipment and materials specification and cost estimate documents.

Engineers who design know installation

Our designers work alongside installers and commissioning engineers. That is why our designs reflect real conditions: how a cable route can be run, where service access will be, how the system will behave during commissioning. For Siemens and Esser systems we design to the manufacturers' methods as certified engineers.

Approval support and designer supervision

We support the design through approvals, respond to review comments and provide designer supervision during installation, so the system is installed as intended.

Codes and standards

DBN V.2.5-56:2014DBN V.1.1-7:2016DBN A.2.2-3DSTU B A.2.4-4DSTU EN 54

FAQ

Design FAQ

Does a fire alarm system need a design?

Yes. Fire protection systems are installed according to a design prepared in line with current codes. The design is needed for installation, commissioning and inspections.

How long does design take?

It depends on the area, complexity and number of systems. A small site takes from a few days; a large complex with several systems takes a few weeks. Deadlines are fixed in the contract.

Can you install a system from someone else's design?

Yes. Before installation we check the design against the codes and the actual site and propose corrections if needed.

Do you design for renovation projects?

Yes. We survey the existing systems and develop an upgrade design that keeps what can be kept and allows phased work without shutting down the facility.

Contacts

Tell us about your site

We reply during business hours and can visit the site if needed. The consultation is free.

Address
15 Yakuba Kolasa St., Kyiv, Ukraine
Hours
Mon–Fri 9:00–18:00 · 24/7 emergency line

Leave a phone number or email so we can reply.