Fire protection

Smoke extraction and smoke control

We handle smoke control system design and installation: smoke extraction and pressurization that keep escape routes free of smoke, working on one logic with the fire alarm.

Smoke ventilationPressurizationDampersDSTU EN 12101Controls

Why smoke control matters

In a fire, most people are harmed not by flames but by smoke. Combustion products fill corridors and stairs within minutes, reduce visibility and poison. A smoke control system keeps escape routes usable and lets fire crews do their job.

What the system consists of

  • Smoke extraction fans rated for the required temperature and operating time.
  • Smoke dampers and fire dampers with electric actuators.
  • Pressurization fans for stairwells, elevator shafts and lobbies.
  • Ductwork with the required fire resistance rating.
  • Control panels for fans and dampers, and cables with the required fire resistance.
  • Make-up air, so the system removes smoke instead of creating negative pressure that jams doors.

Calculations and design

A smoke control system is never sized "by eye". We run an airflow calculation for each zone: smoke volume, flow velocity, pressure losses, pressure difference across doors. Based on the calculation we select fans and dampers and design the ductwork and control logic.

Controls and integration

The best equipment will not help if the control logic is wrong. We program it so that on a fire alarm signal the dampers open only in the zone where the fire started, the fire dampers of the general ventilation close, and the smoke extraction and pressurization fans start in the correct sequence.

We integrate the system with the fire alarm, building management (BMS) and elevators, and bring the status of every damper and fan to the control room.

Commissioning

After installation we carry out integrated testing: every actuator, the control logic and the airflow parameters are checked. We hand over as-built documentation and test reports and train your staff.

Codes and standards

DBN V.2.5-56:2014DBN V.1.1-7:2016DSTU EN 12101DBN V.2.5-67

FAQ

Smoke control FAQ

Where is a smoke extraction system required?

Building codes set the requirements based on occupancy, number of floors, room areas and the availability of natural ventilation. Typical cases are corridors without natural light, stairwells, atriums, underground parking and large halls. The design gives the exact answer.

What is the difference between smoke extraction and pressurization?

Smoke extraction removes smoke from the fire zone, while pressurization creates positive pressure in stairwells, elevator shafts and lobbies so smoke cannot get in. The two systems usually work together.

What starts smoke extraction during a fire?

Automatically, a signal from the fire alarm. Remote start from push buttons and the control room is also provided. We program the logic so the system opens the right dampers and starts the right fans in the fire zone.

How is a smoke control system tested?

At commissioning, airflow tests and logic checks are carried out. After that the system is regularly serviced and tested according to the maintenance schedule.